Reverberation Time (RT60)
RT60 of a room by Sabine and Eyring from its dimensions and the absorption coefficients you enter for floor, ceiling and walls, plus extra absorption.
The reverberation time by Sabine and by Eyring, the total absorption and mean absorption coefficient, the room’s volume and surface, and the Schroeder frequency below which room modes dominate.
Example: A 6 × 5 × 3 m room with a 0.3 floor, 0.1 ceiling, 0.05 walls and 5 m² of furniture has an RT60 of 0.71 s by Sabine and 0.65 s by Eyring.
Volume over
absorption.
How the decay time follows from volume and absorption, why the two formulas differ, where the coefficients come from, and what the Schroeder frequency means.
Sabine and Eyring
Sound decays by 60 dB in RT60 = 0.161·V ÷ A seconds (0.049 in feet), with V the volume and A the total absorption — each surface’s area times its absorption coefficient, plus furniture, panels and people in square-metre or square-foot sabins. Eyring’s version, 0.161·V ÷ (−S·ln(1 − ᾱ)), is more accurate once the room is well damped.
Coefficients
An absorption coefficient is the share of sound a surface absorbs, and it changes strongly with frequency — carpet absorbs little bass and much treble. The page stores none: take each material’s figure for one octave band from its data and repeat for each band you care about.
What the number does not settle
Both formulas assume sound spread evenly through the room; below the Schroeder frequency, 2000·√(RT ÷ V), individual room modes decide the bass instead. Inputs stay in your browser; the same anonymous usage counts as the rest of the site apply.